Fuse ArCon SF

The fuse from Sykonec is available in two options:
Coverd with cross-linked material - pluggable with pre-harnessed.

For covering the cables Sykonec fuse uses the identical materials as for the sheath of the solar cable.
The process of vulcanization leads to irreversible, chemical cross linking between the materials.

Removable - Fitted in the PV-Stringsystems or as an assembly kit.

 

 

ArCon SF Advantages

  • Overcurrent protection
  • Protects strings from reverse current overload caused by earth faults, short circuits or incorrect installation
  • Premium quality directly from the manufacturer
  • Tailor-made solutions
  • Assembly according to customer’s specifications
  • Released by Jurchen Technology in combination with all components listed on the data sheet

Fuse ArCon SF Technical data

1. Electrical data
Fuse characteristic PV (PV-Fuse)
Rated current Up to 30 A (depending on the fuse being used)
Rated voltage Up to 1500 VDC (depending on the fuse being used)
Contact resistance at termination ≤ 10 mΩ
Insulation resistance > 10 GΩ
PV-Fuse manufacturer Siba, Jean Müller, COOPER Bussmann
other manufacturer on request
Tests Spark test in accordance with EN 50395 section 10 with 15kV AC
High voltage test in water in accordance with TÜV 2 PfG 1913/04.11 section 7.3.8 b) with 6,5 KV AC
Contact resistance at termination cc. to test 2b of EN 60512
Insulation resistance in accordance with EN 50395 section 8.1
Long term resistance of insulation to d.c. according to TÜV 2 PfG 1913/04.11 section 7.3.13
240 h at 1.5 kV in salt water at 85°C
2. Thermal data
Ambient temperature range From -40 °C to +90 °C (from -40 °F to +194 °F)
Thermal cycle test Acc. to IEC 60068-2-14, test Nb
Damp heat test Acc. to IEC 60068-2-78
1000 h at 90 °C and 85 % relative humidity
Resistance to cold Cold impact test acc. to TÜV PfG 1913/04.11 section 7.3.9
Degree of protection(IP-Code) IP68 (10 days, 1 m) acc. to IEC 60529
Connection method Crimping
3. Chemical data
Moulding material EVA compound 120 °C based on DIN EN 50363-2-1
Moulding material and cable sheat are crosslinked
Weather resistance Ozone resistance acc. to DIN EN 50396 test type B
UV-resistance acc. to ISO 4892-2 (Method A)
Behaviour in case of fire Flame class V0 acc. to UL94
Single cable burning test acc. to IEC 60332-1-2
Multiple cable burning test acc. to DIN EN 50305-9
Lower smoke emission acc. to DIN VDE 0482 part 268-2, IEC 61034
Halogen free acc. to DIN EN 50264-1
Low toxicity acc. to DIN EN 50305
4. PV-Conductor
Manufacturer Prysmian Kabel und Systeme GmbH
Trademark TECSUN (PV)
Type designation PV1-F
Approvals Requirements for cables for PV systems DKE/VDE AK
411.2.3 - VDE-Reg.No. 7985
TÜV 2 PfG 1169/08.2007 - Cert.-No. R 60013989
Conductor Electrolytic copper, tinned, Class 5 acc. to IEC 60228 (DIN VDE 0295)
Cross section 2,5 mm², 4 mm² und 6 mm²
Tensile strength 15 N/mm2 during operation, 50 N/mm2 during installation
Bending radius Min. 3 x D (D = outer diameter maximum value)
D = 5,1 mm for 2,5 mm² wire cross section
D = 5,6 mm for 4 mm² wire cross section
D = 6,1 mm for 6 mm² wire cross section
Sheath colours Black (red and blue on request)
5. Both-sided connectivity
PV-Connectors Multi Contact - MC3
TÜV certified acc. to EN 50521:2008 / R60026534
Multi Contact - MC4
TÜV-certified acc. to EN 50521:2008 / R60028286
Amphenol - Helios H4
TÜV-Certified acc. to EN 50521:2008 / R50157783
IPC-Connectivity 8x60 mm
Open end
Other connectivity on request